退出Jess条件的执行条件

我正在阅读Jess中的几个用户输入。规则是:退出Jess条件的执行条件

(defrule specify-input 

?act <- (Actuator (name 0) (inputVoltage ?v1&0))

=>

(printout t "Please specify input voltage of the actuator. [V] " crlf)

(modify ?act (inputVoltage (read)))

(printout t "Please specify desired force of the actuator. [N] " crlf)

(modify ?act (Force (read)))

(printout t "Please specify desired stroke lenght of the actuator. [mm] " crlf)

(modify ?act (StrokeLength (read))))

我想能够检查的输入电压的值,如果它超出了规定的范围,将其设置为0并退出进一步规则执行。有没有办法做到这一点?

回答:

您可以使用if函数(参见Jess手册第3.8.2节)。

(printout t "Please specify input voltage of the actuator. [V] " crlf) 

(bind ?v (read))

(if (and (> ?v 0) (<= ?v 1000)) then

(printout t "Please specify desired force of the actuator. [N] " crlf)

(bind ?f (read))

(printout t "Please specify desired stroke lenght of the actuator. [mm] " crlf)

(bind ?sl (read))

(modify ?act (inputVoltage ?iv)(Force ?f)(StrokeLength ?sl))

) else (

(printout t "invalid voltage" crlf)

)

也可以对其他值进行类似的检查。

但不应该给用户另外的机会吗?参看第3.8.1节。

(while true do 

(printout t "Please specify input voltage of the actuator. [V] " crlf)

(bind ?v (read))

(if (and (> ?v 0) (<= ?v 1000)) then (break))

(printout t "invalid voltage, not in (0,1000]" crlf)

)

以上是 退出Jess条件的执行条件 的全部内容, 来源链接: utcz.com/qa/259377.html